{"id":1953,"date":"2026-05-05T05:12:01","date_gmt":"2026-05-05T05:12:01","guid":{"rendered":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/?p=1953"},"modified":"2026-07-20T07:22:14","modified_gmt":"2026-07-20T07:22:14","slug":"midea-aircon-error-codes","status":"publish","type":"post","link":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html","title":{"rendered":"The Ultimate Midea Air Conditioner Error Code Guide (2026 Edition)"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" id=\"p-rc_30b16e802aa8faa9-1951\">Is your Midea air conditioner flashing a cryptic combination of letters and numbers instead of cooling your room? These error codes are built-in diagnostic tools designed to tell you exactly what is wrong with the system, from a simple dirty filter to a complex communication failure<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_30b16e802aa8faa9-1952\">Because Midea produces a wide range of systems\u2014including residential split units, multi-inverters, and commercial water-based heat exchangers\u2014a single code can sometimes mean different things depending on your specific model<sup><\/sup>. This guide provides the most comprehensive breakdown of Midea error codes to help you troubleshoot like a pro.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\" alt=\"Midea air conditioner error code infographic summary for E, F, and P series troubleshooting - Aircon-Servicing.com.sg\" class=\"wp-image-1967\" srcset=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg 1024w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service-300x168.jpg 300w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service-768x429.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Quick Search: Midea Error Code Lookup<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Use this section to identify your code quickly. If you are an advanced user, you can integrate this data into a custom interactive script.<\/em><\/p>\n\n\n\n<!-- MIDEA ERROR CODE LOOKUP TOOL - INTERACTIVE -->\n<div id=\"midea-lookup-wrapper\" style=\"max-width: 800px; margin: 40px auto; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; color: #2d3436; border: 1px solid #dfe6e9; border-radius: 12px; overflow: hidden; box-shadow: 0 10px 25px rgba(0,0,0,0.05); background: #ffffff;\">\n    \n    <!-- Search Header -->\n    <div style=\"background: #004aad; padding: 30px; text-align: center;\">\n        <h2 style=\"color: #ffffff; margin: 0 0 15px 0; font-size: 24px; font-weight: 800;\">Midea Error Code Search<\/h2>\n        <p style=\"color: #ffffff; opacity: 0.9; margin: 0 0 20px 0; font-size: 15px;\">Enter your AC display code (e.g., E1, F5, P2) below:<\/p>\n        <div style=\"position: relative; max-width: 400px; margin: 0 auto;\">\n            <input type=\"text\" id=\"mideaSearchInput\" placeholder=\"Search code...\" onkeyup=\"filterMideaCodes()\" style=\"width: 100%; padding: 15px 20px; border-radius: 50px; border: none; font-size: 18px; font-weight: 600; outline: none; box-shadow: 0 4px 10px rgba(0,0,0,0.15);\">\n        <\/div>\n    <\/div>\n\n    <!-- Results Area -->\n    <div id=\"mideaResultsContainer\" style=\"padding: 20px; max-height: 500px; overflow-y: auto; background: #f8f9fa;\">\n        <!-- Code Card Template -->\n        <div class=\"midea-code-card\" data-code=\"E1\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px; box-shadow: 0 2px 5px rgba(0,0,0,0.03);\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: E1<\/span>\n                <span style=\"background: #e1f0ff; color: #004aad; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700; text-transform: uppercase;\">System Protection<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">High Pressure Protection<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">Check for blocked outdoor units, dirty condenser coils, or refrigerant overcharge.[cite: 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"E2\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: E2<\/span>\n                <span style=\"background: #e1f0ff; color: #004aad; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Sensor \/ Freeze<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Indoor Ambient Sensor Error \/ Anti-freeze Protection<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">Check indoor ambient temperature sensor connection or ensure indoor filters are clean to prevent evaporator freezing.[cite: 3, 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"E3\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: E3<\/span>\n                <span style=\"background: #ffeaa7; color: #d35400; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Pressure Protection<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Evaporator Temp Sensor Error \/ Low Pressure Protection<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">Often indicates low refrigerant levels or a faulty midpoint sensor on the indoor coil.[cite: 3, 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"E4\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: E4<\/span>\n                <span style=\"background: #e1f0ff; color: #004aad; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Sensor Error<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Indoor Temperature Sensor Error<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">The indoor coil thermistor is open or short-circuited. Replacement usually required.[cite: 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"E6\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: E6<\/span>\n                <span style=\"background: #fab1a0; color: #c0392b; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Comm Error<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Communication Error<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">Loss of signal between indoor and outdoor PCB. Check wiring terminals and cable integrity.[cite: 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"F0\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: F0<\/span>\n                <span style=\"background: #ff7675; color: #fff; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Refrigerant<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Refrigerant Leakage Detected<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">The system has detected a significant drop in pressure. Requires leak test and repair.[cite: 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"F5\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: F5<\/span>\n                <span style=\"background: #e1f0ff; color: #004aad; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Fan Motor<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">Outdoor Fan Motor Speed Malfunction<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">The outdoor fan is locked or operating at abnormal speeds. Check for obstructions.[cite: 4]<\/div>\n        <\/div>\n\n        <div class=\"midea-code-card\" data-code=\"P2\" style=\"background: #fff; padding: 20px; border-radius: 8px; margin-bottom: 15px; border-left: 5px solid #c5a059; display: flex; flex-direction: column; gap: 8px;\">\n            <div style=\"display: flex; justify-content: space-between; align-items: center;\">\n                <span style=\"font-weight: 900; font-size: 20px; color: #004aad;\">CODE: P2<\/span>\n                <span style=\"background: #55efc4; color: #00b894; padding: 4px 10px; border-radius: 4px; font-size: 12px; font-weight: 700;\">Drainage<\/span>\n            <\/div>\n            <div style=\"font-weight: 700; color: #2d3436;\">High Water Level \/ Drainage Issue<\/div>\n            <div style=\"font-size: 14px; color: #636e72; line-height: 1.4;\">The drain pan is full or the float switch has triggered. Clear the drain line.[cite: 4]<\/div>\n        <\/div>\n\n        <!-- No Result Message -->\n        <div id=\"noMideaResult\" style=\"display: none; text-align: center; padding: 40px 20px; color: #636e72;\">\n            <p style=\"font-weight: 700; margin-bottom: 10px;\">No code found.<\/p>\n            <p style=\"font-size: 14px;\">Try searching with just the letter or number, or contact a technician for a manual diagnosis.<\/p>\n        <\/div>\n    <\/div>\n<\/div>\n\n<script>\nfunction filterMideaCodes() {\n    const input = document.getElementById('mideaSearchInput');\n    const filter = input.value.toUpperCase();\n    const container = document.getElementById('mideaResultsContainer');\n    const cards = container.getElementsByClassName('midea-code-card');\n    const noResult = document.getElementById('noMideaResult');\n    let foundCount = 0;\n\n    for (let i = 0; i < cards.length; i++) {\n        const code = cards[i].getAttribute('data-code');\n        if (code.toUpperCase().indexOf(filter) > -1) {\n            cards[i].style.display = \"flex\";\n            foundCount++;\n        } else {\n            cards[i].style.display = \"none\";\n        }\n    }\n\n    if (foundCount === 0) {\n        noResult.style.display = \"block\";\n    } else {\n        noResult.style.display = \"none\";\n    }\n}\n<\/script>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>E-Series Error Codes (System &amp; Sensor Protections)<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The &#8220;E&#8221; codes generally point to temperature sensor failures, pressure protections, or communication errors.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-E-Series-Error-Code-Guide-Infographic.jpg\" alt=\"Midea aircon E1, E2, E3, E4, E6, and E7 error code troubleshooting infographic - Aircon-Servicing.com.sg\" class=\"wp-image-1969\" srcset=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-E-Series-Error-Code-Guide-Infographic.jpg 1024w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-E-Series-Error-Code-Guide-Infographic-300x168.jpg 300w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-E-Series-Error-Code-Guide-Infographic-768x429.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">A quick-reference guide for Midea E-Series sensor and system protection faults.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Error Code<\/strong><\/td><td><strong>Description \/ Meaning<\/strong><\/td><td><strong>Possible Causes &amp; Troubleshooting<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>E1<\/strong><\/td><td>High Pressure Protection<sup><\/sup>.<\/td><td>Excessive pressure in the refrigerant system<sup><\/sup>. Ensure the outdoor unit has proper airflow, check for blocked condenser coils, and inspect for refrigerant overcharge<sup><\/sup>.<\/td><\/tr><tr><td><strong>E2<\/strong><\/td><td><em>Split Units:<\/em> Indoor ambient temperature sensor error<sup><\/sup>.<br><br><em>Multi\/Inverter Units:<\/em> Indoor Anti-freeze Protection<sup><\/sup>.<\/td><td><em>Sensor Error:<\/em> The temperature sensor is not connected correctly or is faulty<sup><\/sup>. Check the connection on the main PCB or replace the sensor\/PCB<sup><\/sup>.<br><br><em>Anti-freeze:<\/em> Evaporator coil temperature is too low<sup><\/sup>. Ensure filters are clean, airflow is unobstructed, inspect refrigerant levels, and allow the unit to defrost<sup><\/sup>.<\/td><\/tr><tr><td><strong>E3<\/strong><\/td><td><em>Split Units:<\/em> Indoor heat exchanger midpoint temperature sensor error<sup><\/sup>.<br><br><em>Multi\/Inverter Units:<\/em> Low Pressure Protection<sup><\/sup>.<br><br><em>Commercial\/Water Units:<\/em> Combined water outlet temperature sensor error<sup><\/sup>.<\/td><td><em>Sensor Error:<\/em> The sensor is loose, short-circuited, or failed; reconnect or replace the sensor or main PCB<sup><\/sup>.<br><br><em>Low Pressure:<\/em> Low refrigerant pressure or leakage<sup><\/sup>. Check for leaks, recharge refrigerant, and inspect the expansion valve<sup><\/sup>.<\/td><\/tr><tr><td><strong>E4<\/strong><\/td><td><em>Split Units:<\/em> Indoor heat exchanger outlet temperature sensor error<sup><\/sup>.<br><br><em>Multi\/Inverter Units:<\/em> Indoor Room Temperature Sensor Error<sup><\/sup>.<br><br><em>Commercial\/Water Units:<\/em> Water outlet temperature sensor error<sup><\/sup>.<\/td><td><em>Sensor Error:<\/em> Sensor is in open circuit, short-circuited, or poorly connected<sup><\/sup>. Check the indoor thermistor and associated wiring, and replace the part if defective<sup><\/sup>.<\/td><\/tr><tr><td><strong>E5 \/ 1E5<\/strong><\/td><td><em>Multi\/Inverter Units:<\/em> Overcurrent Protection<sup><\/sup>.<br><br><em>Commercial\/Water Units (1E5):<\/em> Air side heat exchanger refrigerant outlet temperature sensor T3A error<sup><\/sup>.<\/td><td><em>Overcurrent:<\/em> Excessive current in the system<sup><\/sup>. Verify the voltage supply, inspect the compressor and wiring, and restart the unit<sup><\/sup>.<br><br><em>Sensor Error:<\/em> Check for loose connection on main PCB, short-circuit, or failure; replace sensor or PCB<sup><\/sup>.<\/td><\/tr><tr><td><strong>E6<\/strong><\/td><td>Communication Error<sup><\/sup>.<\/td><td>Loss of communication between indoor and outdoor units<sup><\/sup>. Check wiring connections, ensure no damage to communication cables, and restart the system<sup><\/sup>.<\/td><\/tr><tr><td><strong>E7<\/strong><\/td><td>Outdoor ambient temperature sensor error<sup><\/sup>.<\/td><td>Temperature sensor connection on main PCB is loose, short-circuited, or failed<sup><\/sup>. Reconnect or replace the sensor\/PCB<sup><\/sup>.<\/td><\/tr><tr><td><strong>E8<\/strong><\/td><td>Power Phase Protector Fault<sup><\/sup>.<\/td><td>Midea cassette aircon has an airflow or electrical issue<sup><\/sup>. Check wiring connections, ensure no damage to communication cables or terminals, and restart the system<sup><\/sup>.<\/td><\/tr><tr><td><strong>Eb \/ 2Eb<\/strong><\/td><td>Water side heat exchanger anti-freezing temperature sensor Taf2 error<sup><\/sup>.<\/td><td>Sensor connection is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><tr><td><strong>Ed \/ 1Ed \/ 2Ed<\/strong><\/td><td>Discharge pipe temperature sensor of system A error (1Ed) or system B error (2Ed)<sup><\/sup>.<\/td><td>Sensor connection is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><tr><td><strong>EF<\/strong><\/td><td>Water inlet temperature sensor error<sup><\/sup>.<\/td><td>Sensor connection is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><tr><td><strong>EP<\/strong><\/td><td>Discharge pipe temperature sensor failure alarm<sup><\/sup>.<\/td><td>Sensor connection is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><tr><td><strong>EU<\/strong><\/td><td>Air side heat exchanger refrigerant total outlet temperature sensor Tz\/7 error<sup><\/sup>.<\/td><td>Sensor connection is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_e1abaca7ae507e91-2053\">When your Midea air conditioner displays an <strong>E-Series<\/strong> code, it is generally signaling a protection mode or a sensor failure<sup><\/sup>. These codes are designed to prevent permanent damage to the compressor or electronic components<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Here is a step-by-step troubleshooting guide to help you move from a flashing error to a cooling room.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 1: The 10-Minute &#8220;Hard Reset&#8221;<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before opening any panels, perform a power cycle to clear temporary electronic glitches.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Turn off the air conditioner and switch off the main circuit breaker.<\/li>\n\n\n\n<li><strong>Wait:<\/strong> Keep the power off for <strong>at least 10 minutes<\/strong> to allow the control board capacitors to discharge completely.<\/li>\n\n\n\n<li><strong>Result:<\/strong> If the code was caused by a minor power surge or communication hiccup, the unit should restart normally.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 2: Identify the Fault Category<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If the code returns immediately, categorize the error to determine your next move.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Pressure &amp; Airflow Issues (<strong>E1, E3<\/strong>)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>E1 (High Pressure):<\/strong> Often caused by a dirty outdoor unit or blocked air path. Check that no objects are blocking the outdoor fan and clean the condenser coils.<\/li>\n\n\n\n<li><strong>E3 (Low Pressure):<\/strong> Usually indicates a refrigerant leak. Look for oily residue around the copper pipe joints, which signals a gas leak.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Sensor Failures (<strong>E2, E3, E4, E7<\/strong>)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Common Symptoms:<\/strong> The unit may start for a few seconds and then shut down.<\/li>\n\n\n\n<li><strong>Quick Check:<\/strong> Ensure the sensor (thermistor) hasn&#8217;t slipped out of its housing on the copper pipe.<\/li>\n\n\n\n<li><strong>Advanced Troubleshooting:<\/strong> Use a multimeter to check the sensor&#8217;s resistance. If the resistance is near zero (short circuit) or infinite (open circuit), the sensor is dead and must be replaced.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Communication Errors (<strong>E6<\/strong>)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Inspect the signal wire connecting the indoor and outdoor units.<\/li>\n\n\n\n<li><strong>Watch For:<\/strong> Loose terminals, corroded wires, or damage from pests (like lizards or ants) that may have shorted the PCB.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 3: Technical Reference Table<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Error Code<\/strong><\/td><td><strong>Primary Action<\/strong><\/td><td><strong>Technical Check<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>E1<\/strong><\/td><td>Clean outdoor coils<sup><\/sup>.<\/td><td>Check for refrigerant overcharge<sup><\/sup>.<\/td><\/tr><tr><td><strong>E2 \/ E4<\/strong><\/td><td>Reconnect indoor sensors<sup><\/sup>.<\/td><td>Replace faulty indoor thermistor<sup><\/sup>.<\/td><\/tr><tr><td><strong>E3<\/strong><\/td><td>Inspect for gas leaks<sup><\/sup>.<\/td><td>Check indoor midpoint sensor resistance<sup><\/sup>.<\/td><\/tr><tr><td><strong>E6<\/strong><\/td><td>Tighten wiring terminals<sup><\/sup>.<\/td><td>Check signal voltage between units<sup><\/sup>.<\/td><\/tr><tr><td><strong>E8<\/strong><\/td><td>Verify power supply phase<sup><\/sup>.<\/td><td>Check for airflow obstructions in cassettes<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 4: When to Call a Professional<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">While cleaning filters or resetting the breaker is safe for most users, some E-series repairs involve high-voltage electricity and specialized tools.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Contact a technician if:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>You suspect a <strong>refrigerant leak (E3)<\/strong>, as this requires a vacuum pump and manifold gauges.<\/li>\n\n\n\n<li>The <strong>outdoor main PCB (E7, E6)<\/strong> needs replacement.<\/li>\n\n\n\n<li>The error involves <strong>Power Phase (E8)<\/strong>, which requires testing your home\u2019s electrical distribution.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Pro Tip:<\/strong> Always record the specific error code (and if it is flashing or static) before calling for service. This helps the technician bring the correct replacement sensors or boards on the first visit.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>F-Series Error Codes (Outdoor Unit &amp; Fan Faults)<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The &#8220;F&#8221; codes predominantly relate to outdoor sensor faults, motor speed anomalies, and refrigerant leakage.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-F-Series-Outdoor-Refrigerant-Error-Code-Guide.jpg\" alt=\"Midea aircon F0, F1, F2, F3, and F5 error code troubleshooting infographic for outdoor unit repairs - Aircon-Servicing.com.sg\" class=\"wp-image-1971\" srcset=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-F-Series-Outdoor-Refrigerant-Error-Code-Guide.jpg 1024w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-F-Series-Outdoor-Refrigerant-Error-Code-Guide-300x168.jpg 300w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-F-Series-Outdoor-Refrigerant-Error-Code-Guide-768x429.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">A visual guide to Midea F-Series codes involving outdoor fans, sensors, and refrigerant pressure.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Error Code<\/strong><\/td><td><strong>Description \/ Meaning<\/strong><\/td><td><strong>Possible Causes &amp; Troubleshooting<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>F0<\/strong><\/td><td>Refrigerant Leakage<sup><\/sup>.<\/td><td>Insufficient refrigerant due to leakage<sup><\/sup>. Inspect for leaks, then repair and refill refrigerant<sup><\/sup>.<\/td><\/tr><tr><td><strong>F1<\/strong><\/td><td>Indoor Ambient Sensor Fault<sup><\/sup>.<\/td><td>Malfunctioning ambient temperature sensor<sup><\/sup>. Replace the sensor and ensure proper sensor connection<sup><\/sup>.<\/td><\/tr><tr><td><strong>F2<\/strong><\/td><td>Outdoor Temperature Sensor Fault (Condenser)<sup><\/sup>.<\/td><td>Condenser coil temperature sensor is in open circuit or has short circuited<sup><\/sup>. Replace the sensor and ensure proper sensor connection<sup><\/sup>.<\/td><\/tr><tr><td><strong>F3<\/strong><\/td><td>Outdoor Temperature Sensor Fault (Compressor)<sup><\/sup>.<\/td><td>Compressor discharge temperature sensor is in open circuit or has short circuited<sup><\/sup>. Replace the sensor and ensure proper sensor connection<sup><\/sup>.<\/td><\/tr><tr><td><strong>F4<\/strong><\/td><td>Outdoor unit EEPROM parameter error<sup><\/sup>.<\/td><td>Contact a technician to reprogram or replace the EEPROM<sup><\/sup>.<\/td><\/tr><tr><td><strong>F5<\/strong><\/td><td>Outdoor Fan Motor Speed Fault<sup><\/sup>.<\/td><td>The outdoor fan motor speed is operating outside the normal range<sup><\/sup>. Inspect the fan motor for defects and replace if necessary<sup><\/sup>.<\/td><\/tr><tr><td><strong>F6<\/strong><\/td><td>Indoor Temperature Sensor Fault<sup><\/sup>.<\/td><td>Evaporator coil outlet temperature sensor is in open circuit or has short circuited<sup><\/sup>. Replace the sensor and ensure proper connection<sup><\/sup>.<\/td><\/tr><tr><td><strong>F9 \/ 1F9 \/ 2F9<\/strong><\/td><td>Inverter module temperature sensor error (Tfin1 for 1F9, Tfin2 for 2F9)<sup><\/sup>.<\/td><td>Sensor connection on main PCB is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><tr><td><strong>Fb<\/strong><\/td><td>Pressure sensor error<sup><\/sup>.<\/td><td>Pressure sensor connection on main PCB is loose, short-circuited, or failed<sup><\/sup>. Replace main PCB or the sensor<sup><\/sup>.<\/td><\/tr><tr><td><strong>Fd<\/strong><\/td><td>Air suction temperature sensor error<sup><\/sup>.<\/td><td>Sensor connection on main PCB is loose, short-circuited, or failed<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If your unit is flashing an &#8220;F,&#8221; follow this systematic guide to diagnose the issue.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 1: The External Obstruction Check<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before testing electrical components, ensure the outdoor unit can &#8220;breathe.&#8221; This is the most common cause for motor speed errors.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Inspect the outdoor fan for debris like dry leaves, twigs, or plastic bags.<\/li>\n\n\n\n<li><strong>Check:<\/strong> Ensure the outdoor condenser fins are not matted with dust or pet hair, which can cause overheating and trigger sensor faults.<\/li>\n\n\n\n<li><strong>Common Code:<\/strong> <strong>F5<\/strong> (Outdoor Fan Motor Speed Fault).<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 2: The &#8220;Freon&#8221; &amp; Leak Protocol (F0)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_3762a6891b1390fa-2132\">The <strong>F0<\/strong> code is one of the most critical. It indicates the system has detected a drop in refrigerant pressure<sup><\/sup>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Safety Warning:<\/strong> Do <strong>not<\/strong> simply &#8220;top up&#8221; the gas. If the system shows F0, there is a physical hole or a loose joint that must be sealed first.<\/li>\n\n\n\n<li><strong>Action:<\/strong> Look for oily spots on the copper piping or the cooling fins. Refrigerant carries oil; where there is a leak, there is usually a greasy residue.<\/li>\n\n\n\n<li><strong>Fix:<\/strong> A technician must perform a pressure test, weld the leak, and perform a vacuum before recharging the system.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 3: Testing the Thermistors (F1, F2, F3, F6)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">F-series sensors are &#8220;thermistors&#8221;\u2014resistors that change value based on temperature.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Identify the Sensor:<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>F1:<\/strong> Indoor Ambient Sensor.<\/li>\n\n\n\n<li><strong>F2:<\/strong> Outdoor Condenser Coil Sensor.<\/li>\n\n\n\n<li><strong>F3:<\/strong> Compressor Discharge Sensor.<\/li>\n\n\n\n<li><strong>F6:<\/strong> Indoor Coil Outlet Sensor.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Testing:<\/strong> Use a multimeter to measure the Resistance ($\\Omega$). If the sensor reads <strong>0 $\\Omega$<\/strong> (short circuit) or <strong>$\\infty$<\/strong> (open circuit), it is defective and requires replacement.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>F-Series Technical Breakdown<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Error Code<\/strong><\/td><td><strong>Meaning<\/strong><\/td><td><strong>Troubleshooting Action<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>F0<\/strong><\/td><td>Refrigerant Leakage<sup><\/sup><\/td><td>Inspect pipe joints for oil; requires leak repair and refill<sup><\/sup>.<\/td><\/tr><tr><td><strong>F1 \/ F6<\/strong><\/td><td>Indoor Sensor Fault<sup><\/sup><\/td><td>Check connection on indoor PCB; replace thermistor if resistance is abnormal<sup><\/sup>.<\/td><\/tr><tr><td><strong>F2 \/ F3<\/strong><\/td><td>Outdoor Sensor Fault<sup><\/sup><\/td><td>Inspect outdoor condenser\/compressor sensors for corrosion or loose plugs<sup><\/sup>.<\/td><\/tr><tr><td><strong>F4<\/strong><\/td><td>EEPROM Parameter Error<sup><\/sup><\/td><td>Usually requires a replacement of the outdoor main PCB<sup><\/sup>.<\/td><\/tr><tr><td><strong>F5<\/strong><\/td><td>Outdoor Fan Motor Fault<sup><\/sup><\/td><td>Check for fan blade obstructions or a failed fan motor<sup><\/sup>.<\/td><\/tr><tr><td><strong>Fb \/ Fd<\/strong><\/td><td>Pressure or Suction Error<sup><\/sup><\/td><td><em>Commercial units:<\/em> Check pressure sensor connections on the main PCB<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Step 4: The Electrical &#8220;Brain&#8221; Check (F4)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_3762a6891b1390fa-2153\">If you see <strong>F4<\/strong>, the system&#8217;s memory (EEPROM) has corrupted<sup><\/sup>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>The Fix:<\/strong> This is rarely a DIY repair. It indicates the software on the outdoor control board has failed. A technician will need to either reprogram the chip or, more commonly, replace the entire outdoor PCB.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Pro-Tip for 2026 Maintenance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern Midea Inverter systems are highly sensitive to voltage &#8220;noise.&#8221; If you encounter multiple &#8220;F&#8221; codes simultaneously, check the grounding of your outdoor unit. A loose ground wire can cause &#8220;ghost&#8221; sensor errors that disappear once the electrical path is secured.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Need a hand with a stubborn F0 or F5 error?<\/strong> Use the lookup tool above or tap the WhatsApp button to speak with a technician who can run a manifold gauge test on your system.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>P-Series &amp; H-Series Error Codes (Electrical &amp; Module Protections)<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">&#8220;P&#8221; and &#8220;H&#8221; codes indicate severe voltage protections, inverter malfunctions, or physical blockages like drainage and locked motors.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-P-Series-and-H-Series-Hardware-Protection-Guide.jpg\" alt=\"Midea aircon P0, P1, P2, P4, and H6 error code troubleshooting infographic for hardware and drainage repairs - Aircon-Servicing.com.sg\" class=\"wp-image-1974\" srcset=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-P-Series-and-H-Series-Hardware-Protection-Guide.jpg 1024w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-P-Series-and-H-Series-Hardware-Protection-Guide-300x168.jpg 300w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-P-Series-and-H-Series-Hardware-Protection-Guide-768x429.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">A visual breakdown of critical Midea hardware protections, including drainage (P2) and inverter module (P0\/P4) faults.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Error Code<\/strong><\/td><td><strong>Description \/ Meaning<\/strong><\/td><td><strong>Possible Causes &amp; Troubleshooting<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>P0<\/strong><\/td><td>IPM Malfunction<sup><\/sup>.<\/td><td>Wiring defect or fault in the outdoor fan motor or compressor<sup><\/sup>. Ensure proper ventilation and check outdoor PCB terminal and wiring<sup><\/sup>.<\/td><\/tr><tr><td><strong>P1<\/strong><\/td><td>Voltage Protection<sup><\/sup>.<\/td><td>Voltage fluctuations or abnormal supply<sup><\/sup>. Stabilize power supply and install a voltage regulator if necessary<sup><\/sup>.<\/td><\/tr><tr><td><strong>P2<\/strong><\/td><td>Water Drainage Issue<sup><\/sup>.<\/td><td>Clog in the drain line<sup><\/sup>. Empty the drain pan and remove clogs from the drain hose<sup><\/sup>.<\/td><\/tr><tr><td><strong>P4<\/strong><\/td><td>Inverter Module Protection<sup><\/sup>.<\/td><td>Overheating or malfunction of inverter module<sup><\/sup>. Ensure proper ventilation and check inverter module for faults<sup><\/sup>.<\/td><\/tr><tr><td><strong>H6<\/strong><\/td><td>Indoor Fan Motor Malfunction<sup><\/sup>.<\/td><td>Faulty or locked indoor fan motor<sup><\/sup>. Remove obstructions around the fan and replace the fan motor if necessary<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2209\">While the E and F series focus on sensors and environment, the <strong>P-Series<\/strong> and <strong>H-Series<\/strong> represent <strong>Protection<\/strong> and <strong>Hardware<\/strong> faults. These codes are often the system\u2019s &#8220;emergency brakes,&#8221; triggered when the unit detects critical electrical anomalies or physical blockages that could lead to complete mechanical failure<sup><\/sup>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your unit is flashing a &#8220;P&#8221; or &#8220;H&#8221; code, use this guide to determine if you need a screwdriver or a specialist.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 1: Clear Physical Blockages (P2 &amp; H6)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">These codes are often caused by tangible obstructions rather than electronic failures.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">The P2 Drainage Protocol<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2210\">The <strong>P2<\/strong> error is one of the most common service calls, especially in humid climates. It signals that the water level in the internal drain pan has reached a critical limit<sup><\/sup>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Check the drain hose for &#8220;slime&#8221; or algae buildup.<\/li>\n\n\n\n<li><strong>Fix:<\/strong> Use a wet\/dry vacuum to clear the external drain pipe. If the code persists, the internal float switch may be stuck in the &#8220;up&#8221; position.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">The H6 Fan Obstruction<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2213\"><strong>H6<\/strong> indicates the indoor fan motor is locked or malfunctioning<sup><\/sup>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Peer into the air outlet (while power is off). Look for objects like pens, toys, or excessive dust &#8220;clumps&#8221; pinning the fan blade.<\/li>\n\n\n\n<li><strong>Check:<\/strong> Gently spin the fan with a long tool; if it resists or feels &#8220;gritty,&#8221; the bearings have failed and the motor requires replacement.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 2: Stabilize the Power Supply (P1)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2216\">The <strong>P1<\/strong> code is a voltage protection error<sup><\/sup>. Modern Midea inverters require a very stable electrical current to operate their high-frequency compressors.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> Check if other high-draw appliances (like water heaters or ovens) were turned on when the error occurred.<\/li>\n\n\n\n<li><strong>Fix:<\/strong> If your area is prone to &#8220;brownouts&#8221; or voltage spikes, consider installing a dedicated voltage stabilizer for the air conditioning circuit.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 3: Inverter &amp; Module Diagnostics (P0 &amp; P4)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2219\">These are &#8220;Module Protections.&#8221; The IPM (Intelligent Power Module) is the brain that converts your home\u2019s power into the specific frequency needed for the compressor<sup><\/sup>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">P0 &amp; P4 Troubleshooting:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Check Ventilation:<\/strong> If the outdoor unit is installed in a tight balcony or a &#8220;cage,&#8221; heat will build up, causing the Inverter Module to overheat (P4).<\/li>\n\n\n\n<li><strong>Thermal Paste:<\/strong> For advanced users, P0 can sometimes be fixed by applying fresh thermal grease between the IPM and its heat sink on the outdoor PCB.<\/li>\n\n\n\n<li><strong>Wiring:<\/strong> Ensure the compressor terminals are tight. A loose wire here creates &#8220;electrical noise&#8221; that trips the IPM protection.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 4: Verification of the PCB (Commercial Units)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"p-rc_ae47c41b7f619093-2233\">For owners of larger Midea units (30kW+), these codes may relate to specific ports on the main control board<sup><\/sup>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Action:<\/strong> If a &#8220;P&#8221; code persists after resets, a technician should verify connections at ports <strong>CN1, CN16, and CN31<\/strong>.<\/li>\n\n\n\n<li><strong>Note:<\/strong> If the resistance across these ports is abnormal, the main PCB has likely suffered a component failure.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Pro-Tip:<\/strong> P-series errors can sometimes be &#8220;ghost codes&#8221; caused by high humidity affecting the outdoor electronics. If your unit is in a coastal or high-rain area, ensuring the outdoor unit&#8217;s electrical box is properly sealed can prevent these codes from appearing during storms.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Important Troubleshooting Notes for Readers<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Verify the Resistance:<\/strong> When diagnosing sensor errors (like E2, E3, or E4), measure the sensor resistance. If the resistance is too low, the sensor has short-circuited. If the resistance is not consistent with the sensor&#8217;s specific resistance characteristics table, the sensor has failed and must be replaced.<\/li>\n\n\n\n<li><strong>Hard Reset:<\/strong> Sometimes, turning off the air conditioner and restarting it can clear minor errors.<\/li>\n\n\n\n<li><strong>Port Connections:<\/strong> For larger 30kW and 60kW Midea units, sensors are connected to specific ports (CN1, CN16, CN31, CN3, CN10, and CN69) on the main PCB.<\/li>\n<\/ul>\n\n\n\n<!-- MIDEA ERROR CODE FAQ - TECHNICAL SCHEMA -->\n<div class=\"midea-faq-container\" style=\"max-width: 800px; margin: 40px auto; font-family: sans-serif; color: #2d3436;\">\n    <style>\n        .midea-faq-section { background: #ffffff; border: 1px solid #dfe6e9; border-radius: 8px; padding: 30px; }\n        .faq-title { color: #004aad; font-size: 1.8rem; margin-bottom: 25px; border-bottom: 3px solid #c5a059; display: inline-block; }\n        .faq-item { margin-bottom: 20px; padding-bottom: 20px; border-bottom: 1px solid #dfe6e9; }\n        .faq-item:last-child { border-bottom: none; }\n        .faq-question { font-weight: 700; font-size: 1.1rem; color: #00337c; margin-bottom: 10px; display: block; }\n        .faq-answer { font-size: 1rem; line-height: 1.6; }\n    <\/style>\n\n    <section class=\"midea-faq-section\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\">\n        <h2 class=\"faq-title\">Frequently Asked Questions<\/h2>\n\n        <div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n            <span class=\"faq-question\" itemprop=\"name\">How do I reset my Midea aircon error code?<\/span>\n            <div class=\"faq-answer\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n                <div itemprop=\"text\">\n                    The most effective way to clear a temporary error is a &#8220;hard reset.&#8221; Switch off the power at the main circuit breaker for 5\u201310 minutes, then restart the unit to allow the electronics to recalibrate.\n                <\/div>\n            <\/div>\n        <\/div>\n\n        <div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n            <span class=\"faq-question\" itemprop=\"name\">Can I fix a &#8220;P2&#8221; error myself?<\/span>\n            <div class=\"faq-answer\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n                <div itemprop=\"text\">\n                    Yes, a P2 error typically indicates a full drain pan or a clogged hose. You can resolve this by emptying the pan and ensuring the drainage line is clear of obstructions or slime.\n                <\/div>\n            <\/div>\n        <\/div>\n\n        <div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n            <span class=\"faq-question\" itemprop=\"name\">Why does my Midea unit show an E6 error?<\/span>\n            <div class=\"faq-answer\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n                <div itemprop=\"text\">\n                    The E6 code signals a communication failure between the indoor and outdoor units. This is often caused by loose wiring terminals or damaged signal cables that require professional inspection.\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n<\/div>\n\n\n\n<!-- PREMIUM MIDEA ERROR FIX FOOTER CTA -->\n<section style=\"background: linear-gradient(135deg, #0c2975 0%, #0d7dd6 100%); border-radius: 15px; padding: 45px 30px; text-align: center; color: #ffffff; margin-top: 50px; box-shadow: 0 12px 30px rgba(12, 41, 117, 0.2); font-family: sans-serif;\">\n    <h2 style=\"color: #ffffff !important; margin-bottom: 15px; font-weight: 900; font-size: 28px;\">Need Expert Midea AC Repairs?<\/h2>\n    <p style=\"font-size: 17px; margin-bottom: 30px; opacity: 0.9; max-width: 600px; margin-left: auto; margin-right: auto; line-height: 1.5;\">\n        Whether it is an E1 high-pressure fault, a P2 drainage issue, or a flashing communication code, our experienced technicians can diagnose and fix your Midea system efficiently.\n    <\/p>\n    \n    <a href=\"#\" id=\"smart-repair-cta-midea\" style=\"background-color: #25D366; color: #ffffff !important; padding: 18px 35px; border-radius: 50px; font-weight: 800; text-decoration: none; display: inline-flex; align-items: center; gap: 12px; transition: 0.3s; font-size: 18px; border: none; cursor: pointer;\">\n        <svg style=\"width:22px; fill:#fff;\" viewBox=\"0 0 24 24\"><path d=\"M12.031 0C5.383 0 0 5.383 0 12.031c0 2.124.553 4.195 1.604 6.012L.152 24l6.113-1.604c1.737.965 3.705 1.474 5.766 1.474 6.648 0 12.031-5.383 12.031-12.031S18.679 0 12.031 0zm0 21.84c-1.785 0-3.53-.48-5.06-1.385l-.36-.214-3.766.987.998-3.67-.235-.373c-1-1.59-1.527-3.435-1.527-5.325 0-5.46 4.44-9.9 9.9-9.9 5.46 0 9.9 4.44 9.9 9.9 0 5.46-4.44 9.9-9.9 9.9zm5.438-7.44c-.298-.15-1.764-.87-2.037-.97-.273-.1-.47-.15-.67.15-.198.3-.77 1.01-.94 1.22-.17.21-.34.23-.64.08-.3-.15-1.26-.465-2.4-1.485-.885-.79-1.48-1.77-1.65-2.07-.17-.3-.02-.46.13-.61.13-.13.3-.35.45-.52.15-.17.2-.3.3-.5.1-.2.05-.38-.03-.53-.08-.15-.67-1.62-.92-2.22-.24-.59-.49-.51-.67-.52-.17-.01-.37-.01-.57-.01-.2 0-.53.08-.8.38-.27.3-1.04 1.02-1.04 2.49 0 1.47 1.07 2.89 1.22 3.09.15.2 2.11 3.22 5.11 4.52.71.31 1.27.49 1.7.63.72.23 1.37.2 1.89.12.58-.09 1.76-.72 2.01-1.42.25-.7.25-1.3.17-1.42-.08-.12-.27-.19-.57-.34z\"\/><\/svg>\n        BOOK A DIAGNOSTIC REPAIR\n    <\/a>\n<\/section>\n\n<script>\n(function() {\n    const waButton = document.getElementById('smart-repair-cta-midea');\n    const currentUrl = window.location.href;\n    \/\/ Updated pre-filled text for Midea\n    const message = `Hi Aircon-Servicing.com.sg, my Midea aircon is showing an error code and I need assistance. \\n\\nSource: ${currentUrl}`;\n    waButton.href = \"https:\/\/wa.me\/6582548688?text=\" + encodeURIComponent(message);\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Is your Midea air conditioner flashing a cryptic combination of letters and numbers instead of cooling your room? These error codes are built-in diagnostic tools designed to tell you exactly<\/p>\n","protected":false},"author":2,"featured_media":1967,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1953","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50","resize-featured-image"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Midea Aircon Error Codes &amp; Troubleshooting Guide (Singapore)<\/title>\n<meta name=\"description\" content=\"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Midea Aircon Error Codes &amp; Troubleshooting Guide (Singapore)\" \/>\n<meta property=\"og:description\" content=\"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html\" \/>\n<meta property=\"og:site_name\" content=\"Singapore Aircon Servicing\u2122\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-05T05:12:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-20T07:22:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"572\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Elvin Yeo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elvin Yeo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html\"},\"author\":{\"name\":\"Elvin Yeo\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#\\\/schema\\\/person\\\/819d8aa94f9851f9e4a2bd7fa401d342\"},\"headline\":\"The Ultimate Midea Air Conditioner Error Code Guide (2026 Edition)\",\"datePublished\":\"2026-05-05T05:12:01+00:00\",\"dateModified\":\"2026-07-20T07:22:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html\"},\"wordCount\":2916,\"publisher\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\",\"articleSection\":[\"Articles\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html\",\"url\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html\",\"name\":\"Midea Aircon Error Codes & Troubleshooting Guide (Singapore)\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\",\"datePublished\":\"2026-05-05T05:12:01+00:00\",\"dateModified\":\"2026-07-20T07:22:14+00:00\",\"description\":\"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#primaryimage\",\"url\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\",\"contentUrl\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg\",\"width\":1024,\"height\":572,\"caption\":\"A professional HVAC technician uses a high-tech digital tablet to diagnose an \\\"E1\\\" error code on a modern Midea wall-mounted air conditioner.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/articles\\\/midea-aircon-error-codes.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Ultimate Midea Air Conditioner Error Code Guide (2026 Edition)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#website\",\"url\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/\",\"name\":\"Singapore Aircon Servicing\u2122\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#organization\",\"name\":\"Singapore Aircon Servicing\u2122\",\"url\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/logo-aircon-servicing.png\",\"contentUrl\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/logo-aircon-servicing.png\",\"width\":157,\"height\":111,\"caption\":\"Singapore Aircon Servicing\u2122\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.aircon-servicing.com.sg\\\/#\\\/schema\\\/person\\\/819d8aa94f9851f9e4a2bd7fa401d342\",\"name\":\"Elvin Yeo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g\",\"caption\":\"Elvin Yeo\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Midea Aircon Error Codes & Troubleshooting Guide (Singapore)","description":"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html","og_locale":"en_US","og_type":"article","og_title":"Midea Aircon Error Codes & Troubleshooting Guide (Singapore)","og_description":"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.","og_url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html","og_site_name":"Singapore Aircon Servicing\u2122","article_published_time":"2026-05-05T05:12:01+00:00","article_modified_time":"2026-07-20T07:22:14+00:00","og_image":[{"width":1024,"height":572,"url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg","type":"image\/jpeg"}],"author":"Elvin Yeo","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elvin Yeo","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#article","isPartOf":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html"},"author":{"name":"Elvin Yeo","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#\/schema\/person\/819d8aa94f9851f9e4a2bd7fa401d342"},"headline":"The Ultimate Midea Air Conditioner Error Code Guide (2026 Edition)","datePublished":"2026-05-05T05:12:01+00:00","dateModified":"2026-07-20T07:22:14+00:00","mainEntityOfPage":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html"},"wordCount":2916,"publisher":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#organization"},"image":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#primaryimage"},"thumbnailUrl":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg","articleSection":["Articles"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html","url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html","name":"Midea Aircon Error Codes & Troubleshooting Guide (Singapore)","isPartOf":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#website"},"primaryImageOfPage":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#primaryimage"},"image":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#primaryimage"},"thumbnailUrl":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg","datePublished":"2026-05-05T05:12:01+00:00","dateModified":"2026-07-20T07:22:14+00:00","description":"Is your Midea aircon flashing an E1, P4, or EC code? Find the exact meaning and DIY fix for all Midea inverter models with our interactive lookup tool.","breadcrumb":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#primaryimage","url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg","contentUrl":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2026\/05\/Midea-AC-Error-Code-Professional-Diagnostic-Service.jpg","width":1024,"height":572,"caption":"A professional HVAC technician uses a high-tech digital tablet to diagnose an \"E1\" error code on a modern Midea wall-mounted air conditioner."},{"@type":"BreadcrumbList","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/articles\/midea-aircon-error-codes.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/"},{"@type":"ListItem","position":2,"name":"The Ultimate Midea Air Conditioner Error Code Guide (2026 Edition)"}]},{"@type":"WebSite","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#website","url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/","name":"Singapore Aircon Servicing\u2122","description":"","publisher":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#organization","name":"Singapore Aircon Servicing\u2122","url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#\/schema\/logo\/image\/","url":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2025\/02\/logo-aircon-servicing.png","contentUrl":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-content\/uploads\/2025\/02\/logo-aircon-servicing.png","width":157,"height":111,"caption":"Singapore Aircon Servicing\u2122"},"image":{"@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/#\/schema\/person\/819d8aa94f9851f9e4a2bd7fa401d342","name":"Elvin Yeo","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3c65b08ef06f732986cd4aa56a685ebc730e4cd876050360fc98886437030a90?s=96&d=mm&r=g","caption":"Elvin Yeo"}}]}},"_links":{"self":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/posts\/1953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/comments?post=1953"}],"version-history":[{"count":10,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/posts\/1953\/revisions"}],"predecessor-version":[{"id":1975,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/posts\/1953\/revisions\/1975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/media\/1967"}],"wp:attachment":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/media?parent=1953"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/categories?post=1953"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.aircon-servicing.com.sg\/wp-json\/wp\/v2\/tags?post=1953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}