{"id":318,"date":"2020-05-06T16:34:24","date_gmt":"2020-05-06T08:34:24","guid":{"rendered":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/dev.firetronics.com.sg\/?page_id=318"},"modified":"2021-04-22T15:39:05","modified_gmt":"2021-04-22T07:39:05","slug":"sprinkler","status":"publish","type":"page","link":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/sprinkler\/","title":{"rendered":"Sprinkler"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row][vc_column][vc_column_text]A\u00a0<strong style=\"color: #ac0f15;\">fire sprinkler<\/strong>\u00a0is the component of a\u00a0<a title=\"Fire Sprinkler System\" href=\"https:\/\/en.wikipedia.org\/wiki\/Fire_sprinkler_system\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">fire sprinkler system<\/a>\u00a0that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.<\/p>\n<p>A\u00a0fire sprinkler system\u00a0is an\u00a0<a title=\"Active Fire Protection\" href=\"https:\/\/en.wikipedia.org\/wiki\/Active_fire_protection\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">active fire protection<\/a>\u00a0measure, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which\u00a0<a title=\"Fire Sprinklers\" href=\"https:\/\/en.wikipedia.org\/wiki\/Fire_sprinkler\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">fire sprinklers<\/a>\u00a0are connected. Fire sprinkler systems\u00a0is most commonly used in manufacturing and commercial industries.\u00a0 It is important that organizations ensure that properties, assets and lives are well protected in the event of unforeseen circumstances, such as a fire.<\/p>\n<p>It is essential to engage an experienced &amp; professional installer to provide proper advices as complications will arise even with the slightest errors made in calculations, installations, or the designing of the fire sprinkler system.<\/p>\n<p>Firetronics has good expertise in supplying fire sprinklers or installing fire sprinkler system for our clients. Our specialists will be able to provide a comprehensive consultation on the installation of fire sprinkler system, erection of a new building or A&amp;A works \u2013 be it concealed or exposed.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<div class=\"table-spri-div\">\n<table class=\"table-sprinklers\" width=\"100%\">\n<thead>\n<tr>\n<th>Max. Ceiling Temperature<\/th>\n<th>Temperature Rating<\/th>\n<th>Temperature Classification<\/th>\n<th>Color Code (with Fusible Link)<\/th>\n<th>Liquid Alcohol in Glass Bulb Color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>100\u00b0F \/ 38\u00b0C<\/td>\n<td>135-170\u00b0F \/ 57-77\u00b0C<\/td>\n<td>Ordinary<\/td>\n<td>Uncolored or Black<\/td>\n<td><strong>Orange (135\u00b0F \/ 57\u00b0C) or Red (155\u00b0F \/ 68\u00b0C)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>150\u00b0F \/ 66\u00b0C<\/td>\n<td>175-225\u00b0F \/ 79-107\u00b0C<\/td>\n<td>Intermediate<\/td>\n<td>White<\/td>\n<td><strong>Yellow (175\u00b0F \/ 79\u00b0C) or Green (200\u00b0F \/ 93\u00b0C)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>225\u00b0F \/ 107\u00b0C<\/td>\n<td>250-300\u00b0F \/ 121-149\u00b0C<\/td>\n<td>High<\/td>\n<td>Blue<\/td>\n<td><strong>Blue<\/strong><\/td>\n<\/tr>\n<tr>\n<td>300\u00b0F \/ 149\u00b0C<\/td>\n<td>325-375\u00b0F \/ 163-191\u00b0C<\/td>\n<td>Extra high<\/td>\n<td>Red<\/td>\n<td><strong>Purple<\/strong><\/td>\n<\/tr>\n<tr>\n<td>375\u00b0F \/ 191\u00b0C<\/td>\n<td>400-475\u00b0F \/ 204-246\u00b0C<\/td>\n<td>Very Extra high:<\/td>\n<td>Green<\/td>\n<td><strong>Black<\/strong><\/td>\n<\/tr>\n<tr>\n<td>475\u00b0F \/ 246\u00b0C<\/td>\n<td>500-575\u00b0F \/ 260-302\u00b0C<\/td>\n<td>Ultra High<\/td>\n<td>Orange<\/td>\n<td><strong>Black<\/strong><\/td>\n<\/tr>\n<tr>\n<td>625\u00b0F \/ 329\u00b0C<\/td>\n<td>650\u00b0F \/ 343\u00b0C<\/td>\n<td>Ultra High<\/td>\n<td>Orange<\/td>\n<td><strong>Black<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>[\/vc_column_text][vc_column_text]From Table 6.2.5.1\u00a0<a title=\"NFPA\" href=\"https:\/\/en.wikipedia.org\/wiki\/National_Fire_Protection_Association\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">NFPA<\/a>13 2007 Edition indicates the maximum ceiling temperature, nominal operating temperature of the sprinkler, color of the bulb or link and the temperature classification.[\/vc_column_text][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-322 size-large\" title=\"Fire Sprinkler\" src=\"\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1-1024x512.jpg\" alt=\"Fire Sprinkler\" width=\"1024\" height=\"512\" srcset=\"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1-1024x512.jpg 1024w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1-600x300.jpg 600w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1-300x150.jpg 300w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1-768x384.jpg 768w, https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-content\/uploads\/2020\/05\/rp-sprinklers-1.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]A\u00a0fire sprinkler\u00a0is the component of a\u00a0fire sprinkler system\u00a0that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by fire sprinklers, over 99% of fires were controlled&hellip;<\/p>\n","protected":false},"author":1,"featured_media":453,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"rs_blank_template":"","rs_page_bg_color":"#ffffff","slide_template_v7":"","footnotes":""},"categories":[],"tags":[],"class_list":["post-318","page","type-page","status-publish","has-post-thumbnail","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/pages\/318","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/comments?post=318"}],"version-history":[{"count":11,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/pages\/318\/revisions"}],"predecessor-version":[{"id":563,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/pages\/318\/revisions\/563"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/media\/453"}],"wp:attachment":[{"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/media?parent=318"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/categories?post=318"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/glutenfreepleasure.com\/__proxy_domain\/www.firetronics.com.sg\/wp-json\/wp\/v2\/tags?post=318"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}