Page 104 - Catalog2022
P. 104
MAIN POWER PROTECTION DATA and SIGNAL PROTECTION
Product selector - Service entrance to terminal equipment Product selector - Data / Signal line protection PROTECTION DEVICES
Installation Locations Selection guide - data/signal systems Installation locations
Service entrance - after meter Sub Distribution Board (SDB) - Critical terminal equipment - Critical terminal equipment -
Sturcture configuration - typical Main Distribution Board (MDB) located > 10m from MDB located > 10 m from SDB Common applications Service entrance located >20 m from service entrance Circuit Protection Devices and Control
Circuit Protection De
No external lightning protection system LPS fitted,
3 Phase 415V TN-S or TN-C-S mains supply -
RS 232 Data interfaces ESP 15D Series
underground supply feed
- Twisted pair data protection ESP 15D/BX Series
ESP LA Series
Compact for limited space ESP SL15 Series
Ground
Level ESP 415 D1 Series or ESP 415 M1 Series
Power
For 3 Phase 415V supplies
See pages 11/10 and 11/14
Multiple line protection
ESP 15Q Series
PROTECTION DEVICESvices and Control
No external lightning protection system LPS fitted, ESP 415 D1 Series
3 Phase 415V TN-S or TN-C-S mains supply - For 3 Phase 415V supplies.
exposed overhead supply feed See page 11/10.
RS 422 & RS 423 Data interfaces
ESP 06E Series
ESP SL06 Series ESP LB Series
ESP MC Series
Power
Hospital/Laboratory/Server
Ground RS 485 Data interfaces
Level equipment. See page 11/26. ESP RS485 Series
ESP 415/III/TNS Series or where electronics ESP SL RS485 Series ESP LB Series
are located near MDB before SDB use ESP RS485Q Series
ESP 415 M2 Series
See pages 11/6 and 11/12
ESP 415 M1 Series PBX systems terminating on LSA-Plus ESP KS Series
For 3 Phase 415V supplies. disconnection modules KE Series
External lightning protection system LPS fitted,
multiple connected metallic services (gas/water/ See page 11/14.
data/telecom) 3 Phase 415V TN-S or TN-C-S mains
Computer networks, including Power over Ethernet (PoE)
supply ESP Cat-5 Series
(see Furse Application Note AN004) ESP LN Series
LPS ESP Cat-6 Series
ESP MC/TN/RJ11 Series
Ground ESP 415 D1 Series or For 3 Phase 415V Fax machines/Modems Protectors for specific systems
Level See page 11/26.
Power supplies ESP 415 M1 Series
Data Water System Protector System Protector
Telecom Gas See pages 11/10 and 11/14
ESP 240 D1 Series
For single phase 240V
External lightning protection system LPS fitted, ESP 415/I/TNS Series 4-20 mA loops and low current ESP SL Series DC systems up to 110V, 4A ESP H Series
metallic gas/water/ data/telecom services -unknown for LPS to LPL level I and II supplies. See page 11/6. telemetry systems - Compact, ESP SL LED 4-20mA Series
3 Phase 415V TN-S or TN-C-S mains supply for limited space
ESP 415/III/TNS Series
for LPS to LPL level III
LPS
and IV or where electronics
are located near MDB Multiple line and PBX protection ESP D & Q Series DC systems up to 110V, 0.75 A ESP SL LED Series
before SDB use ESP KS Series - Compact, for limited space
Ground
Level ESP 415 M2 Series for
Power
LPS to LPL level III & IV ESP MC/Cat-5e Series
Unknown
are located near MDB Computer network hubs
ESP 240 M1 Series Hazardous area (process control, ESP SL X Series 3-wire systems - ESP SL/3W Series
before SDB For single phase 240V See page 11/26. fire & gas detectors, 4-20 mA Compact for limited space
ESP 415 M4 Series for supplies. See page 11/14. loops, shut down systems)
LPS to LPL level I & II are
located near MDB RTD systems ESP RTD Series
(see Furse Application Note ESP SL RTD Series
See pages 11/4 and 11/12
AN001) ESP RTDQ Series
Mains protectors for specific sytems
Fire/intruder alarm panels and CCTV systems Photovoltaic (solar) panels Data interfaces at PCB level
ESP PCB Series
(see Furse Application Note
AN003)
ESP In line mains up to 32 Amps. ESP PV Series
See pages 11/22 & 11/24 Photovoltaic RF radio and antenna ESP RF Series
Fire/Intruder alarm panels (solar) panels communication systems
See page 11/20 See page 14/8.
102 103