Page 244 - Catalog2022
P. 244
DIN Series Charger
MEAN WELL MEAN WELL
20A & 40A Peripheral Module 120~230W Portable Battery Charger
20A Power Supply Redundancy Module 40A DC UPS Module DC Power Supply & UPS
Suitable for redundant operation of 24V system Battery controller for DIN rail UPS system
Installed on DIN rail TS-35 / 7. 5 or 15 Parallel connected to DC BUS
Suitable for 24V system up to 40A
Relay contact signal output and LED indicator for input failure
alarm Installed on DIN Rail TS-35 / 7.5 or 15
Built-in battery test function
Cooling by free air convection
DC Power Supply & UPS
Battery polarity protection
3 years warranty
Relay contact signal output and LED indicator for DC BUS
OK, Battery Fail, and Battery Discharge
Cooling by free air convection
3 years warranty
Features
CASE: 923C CASE: 923D
55.5x 125.2x 100 mm 55.5x 125.2x 100 mm
DC input / DC bus ............. 24~29V, 40A max.
DC input voltage range ....... 21~28V, 20A max. x 2 channels Battery input voltage ......... 21~29V General Specification (Please refer to www.meanwell.com for detail spec.)
Reverse voltage ................ 30V Battery input Current ......... 0~40A
DC output current .............. 20A max. Charge current (typ.) ......... 2A PA/B-120 PB-230
DC output voltage drop ...... 0.6V max. External battery (typ.) ....... 24V, 4AH / 7AH / 12AH
Input voltage alarm ............ When input is > 20V(±5%) and DC bus ok ........................ Relay status : Short when DC voltage between AC input voltage range 88~132VAC/ 176~264VAC selectable by switch 90~264VAC; 127~370VDC
<30V(±5%), 21~29V(±3%), relay contacts
Relay contact rating ........... relay contacts LED(Green) : DC bus OK : light; AC inrush current (max.) Cold start, 50A at 230VAC
Working temperature .......... 30VDC, 1A DC bus fail : dark Overload protection 90%~110% constant current limiting ,auto-recovery
Safety standard ................. -40~+70°C Battery fail ....................... Relay status : Short when battery failure is
EMC standards .................. UL508 approved observed through the battery Over voltage protection 108%~127% hiccup mode, auto-recovery 102%~125% shut down o/p voltage, auto-recovery
Connection ........................ EN55032 class B, EN61000-4- test function, relay contacts Setup, rise, hold up time 1000ms, 50ms, 16ms at full load and 230VAC NA
2,3,4,5,6,8,11 LED(Red) : Battery over-discharge warning
I/P: 4 poles, O/P: 2 poles screw DIN or battery broken: light; Withstand voltage I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC
terminal, Battery OK: dark Working temperature -10~+45°C (refer to output derating curve) -20~+50°C (refer to output derating curve)
Single output: 4 poles Battery discharge ............. Relay status : Short when battery in discharge
condition, relay contacts Safety standards UL1012(PB-230xx-AD1 only),
LED(Yellow) : Battery discharging: light; TUV EN60950-1, PSE J60950-1 approved
R
Reverse VoltageReverse Voltageeverse Voltage
Battery is not discharging or EMC standards
DR-RDN20 24V, 20A 30V max. 20A max. discharging current <2A: dark
216x 96.5x 40
Working temperature ......... -20~+70°C Dimension (LxWxH) (mm) Case Type: 180x 96x 49; PCB Type: 144x 90x 35 190x 96x 49
EMC standards ................. EN55032 class B, EN61000-4-2,3,4,5,6,8,11
Connection ...................... I/P: 2 poles, O/P: 2 poles screw DIN terminal,
Single output: 6 poles
DC BUS VoltageC BUS VoltageC BUS Voltage
D D
Model No.odel No.odel No. D D DC BUS CurrentC BUS CurrentC BUS Current
M M
DR-UPS40 24~29V 40A max
PA/B-120 Series PB-230 Series
To satisfy our customers is our goal
High Quality Low Cost P -120 -13 13.8V, 0~7.2A ±3~±8.5% 150mV 73% PB-230-12 14.4V, 0~16A 81.5%
Prompt Delivery Best Service P -120 -27 27.6V, 0~4.3A ±1~±8.0% 200mV 79% PB-230-24 28.8V, 0~8A 85.5%
P -120 -54 55.2V, 0~2.2A ±1~±7.5% 250mV 79% PB-230-48 57.6V, 0~4A 86.0%
= Blank, AD1; Blank= XLR 4P, male type, AD1= Anderson connector
242 243